Develop

Ticket #2138 (closed defect: worksforme)

Opened 12 months ago

Last modified 10 months ago

LXNAV V7 in 6.3.6 Android

Reported by: bobfletcher90 Owned by: max
Priority: normal Milestone: XCSoar 6.3
Component: Other Version: 6.3
Keywords: Cc:

Description (last modified by max) (diff)

The IOIO driver in 6.3.6 for LX/Colibri loads but does not find any data.

The diver status message says No Data. The monitor shows no NMEA data at most speeds, occasionally some garbled data appears. The testing was mostly done at the Flarm default speed of 19200 from the V7.

Changing to the generic driver at the same speed provided the normal data.

Back revving to 6.3.5 worked too.

The Anroid hardware was a Kyobo eReader.

Regards,
Bob

Change History

comment:1 Changed 11 months ago by max

  • Owner set to max
  • Status changed from new to assigned

LXNav has promised to send test hardware. Waiting for it.

comment:2 follow-up: ↓ 3 Changed 11 months ago by max

I have received a V7 today from LXNav. It works well with the LX driver.

Please elaborate how you connected the V7 to the IOIO board. Which cable, which V7 connector? Is there a GPS connected on the GPS port? What are the port settings in the V7?

comment:3 in reply to: ↑ 2 Changed 11 months ago by bobfletcher90

Replying to max:

I have received a V7 today from LXNav. It works well with the LX driver.

Please elaborate how you connected the V7 to the IOIO board. Which cable, which V7 connector? Is there a GPS connected on the GPS port? What are the port settings in the V7?

Max,
Using a Flarm to drive the V7 at the default rate of 19,200. The TTL op from the V7 drives an IOIO board. It strange that the same configuration works fine in 6.3.5 but stopped working in my config in 6.3.6.

The V7 is running f/w 1.99.

What other data would you like?

Regards,
Bob

comment:4 Changed 11 months ago by max

You did not answer all of my questions. I can only help you if you answer all of them. The only question you answered was "Is there a GPS connected on the GPS port?"

Which PDA baud rate is configured in the V7? Which baud rate did you configure in XCSoar?

comment:5 Changed 10 months ago by max

  • Status changed from assigned to closed
  • Resolution set to worksforme
  • Description modified (diff)
Note: See TracTickets for help on using tickets.